EKey Fingerscan Access Control System Manuel d'utilisateur Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
7
ekey multi wiring
OntherstandthelastdeviceintheRS485bus,theterminationswitchhastobeseton„ON“.
optional
First device
in the bus
(chain)
Devices
in the
middle of
the bus
Depending on the
conguration,0to3
units can be
placed here
Last device
in the bus
(chain)
Cable recommendation
J-Y(ST)Y 4 x 2 x 0.8
Wire assignment:
2x RS485 bus; 2x RS485 back-up wires
2x power supply; 2x back-up wires for increased
cross section when cable length is above 50m
RS485: serial
wiring (in a line)
max. 500m
NO STAR-SHAPED
WIRING!
Notebook/PC with
software
ekey FWupdate
CP
DRM
multi
FS WM 2.0
FS OM
FS IN 2.0
FS OM
Up to 4 ekey home nger scanners
connected to 1 ekey multi control panel
Vue de la page 6